Reverse polarity check connection, Connection break down, Short error break down – ProgressiveRC 1010B+ iCharger User Manual
Page 27: Input voltage low voltage, Input voltage over voltage, Balance port cell low vol, Balance port cell high vol, Balance port not connect, Battery check low voltage, Battery check over voltage
 
 
 
-27-
iCharger Synchronous Balance Charger/Discharger 1010B+
Error messages
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The output is connected to a battery with incorrect polarity 
 
 
This will be displayed when an interruption of the connection between 
battery and the charger output has been detected during charging or 
discharging. 
 
 
A short-circuit at output. Please check the charging leads. 
 
 
 
The input voltage is below the limit set in the USER SET menu. 
 
 
 
The input voltage is over the limit (18V). 
 
 
The voltage of one of the cells in the Lithium battery pack is too low. 
Please check the cell voltages one by one. 
 
 
The voltage of one of the cells in the Lithium battery pack is too high. 
Please check the cell voltages one by one. 
 
In Balance charge mode, no battery is connected to the charger‘s balance 
port. 
 
 
Without using the balance port, the cell count detected by the charger is 
less than that set by the user. 
Please check the cell count of the battery pack. 
 
Without using the balance port, the cell count detected by the charger is 
higher than that set by the user. 
Please check the cell count of the battery pack. 
 
The internal temperature is over 65℃(149
o
F). Cool down the unit.
 
 
 
The external temperature sensor detects (battery) temperature above the 
limit. 
 
 
The capacity (mAh) charged or discharged reached the configured 
protection limit. 
 
 
The charge or discharge time reached the configured protection limit. 
 
REVERSE POLARITY
CHECK
CONNECTION
CONNECTION 
 BREAK DOWN 
SHORT ERROR 
 BREAK DOWN 
INPUT VOLTAGE
LOW VOLTAGE
INPUT VOLTAGE
OVER VOLTAGE
BALANCE PORT
CELL LOW VOL
BALANCE PORT 
 CELL HIGH VOL
BALANCE PORT
NOT CONNECT
BATTERY CHECK
LOW VOLTAGE
BATTERY CHECK
OVER VOLTAGE
Int. TEMP OVER
CHG STOPPED
Ext. TEMP OVER
CHG STOPPED
CAPACITY OVER
STOPPED
SAFETY TIME OUT
STOPPED