Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual
Page 57

Using Revolution®
53
Figure 5-5. Rice Lake Web Update Display
Click on the
Check for Updates
button in the Rice Lake
Web Update application to check if a new version of
the
820i
software is available. To download a new
software version, select the new software version and
click on
Get Selection
. Once the new software is
downloaded to the PC, do the following:
1. Disconnect power to the
820i
.
2. Open the indicator enclosure and place a
jumper across the SW1 boot mode pins (see
3. Connect the PC serial port to port 2 of the
820i
.
4. Power up the
820i
. The indicator will stall at
the diagnostic monitor.
5. Click on the
Update Indicator
button to
download the new software. When the
download begins, the following messages are
shown:
Loading…
System Diagnostic Monitor v1.0
$
?
$
?
$KNIX
$SYSLOAD
6. When the download is complete, the indicator
display shows the following messages:
$DONE
$BOOT
Loading…
7. The indicator resets and goes to weigh mode.
8. Disconnect power to the indicator. Remove
the jumper from across the SW1 boot mode
pins and place it on a single pin.
9. Power up the indicator and reload
Revolution
and
iRite-IDE
files as necessary.