Rice Lake 880 Performance Series Panel Mount Indicator/Controller - DeviceNet Interface Option Installation and Programming Manual User Manual
Page 14

10 DeviceNet Installation and Programming Manual
Decimal
Hex
Command
0
0x000
Return Status and Weight (integer)
1
0x001
Display Channel
2
0x002
Display Gross Weight
3
0x003
Display Net Weight
9
0x009
Gross/Net key press (toggle)
10
0x00A
Zero (see note)
11
0x00B
Display Tare (see note)
12
0x00C
Enter Tare (see note)
13
0x00D
Acquire Tare (see note)
14
0x00E
Clear Tare (see note)
16
0x010
Primary Units
17
0x011
Secondary Units
18
0x012
Tertiary Units
19
0x013
Units key press (toggle units)
20
0x014
Print Request
21
0x015
Display Accumulator
22
0x016
Clear Accumulator
23
0x017
Push Weight to Accumulator
32
0x020
Return Gross (integer)
33
0x021
Return Net (integer)
34
0x022
Return Tare (integer)
37
0x025
Return Current Display (integer)
38
0x026
Return Accumulator (integer)
95
0x05F
Set Batching State
96
0x060
Batch Start
97
0x061
Batch Pause
98
0x062
Batch Reset
99
0x063
Batch Status
112
0x070
Lock Indicator Front Panel
113
0x071
Unlock Indicator Front Panel
114
0x072
Set Digital Output ON
115
0x073
Set Digital Output OFF
116
0x074
Read Digital I/O Status
128
0x80
Enable Bus Command Handler
253
0x0FD
No operation
254
0x0FE
Reset Indicator
256
0x100
Return Status and Weight (float)
268
0x10C
Enter Tare (float)
288
0x120
Read Gross (float)
289
0x121
Read Net (float)
290
0x122
Read Tare (float)
293
0x125
Read Current Display (float)
294
0x126
Read Accumulator (float)
Table 3-2. Remote Commands