1 command number, 2 status data, Command number – Rice Lake 880 Performance Series Panel Mount Indicator/Controller - DeviceNet Interface Option Installation and Programming Manual User Manual
Page 16: Status data

12 DeviceNet Installation and Programming Manual
See Section 3.1.1 for BYTE swapping parameters.
3.2.1
Command number
The first word echoes the command number. If the command fails or is not
recognized, the negative of the command number is returned to signal the error.
3.2.2
Status Data
Indicator status data is returned in the second word (see Table 3-4). Batch commands
return batch status in place of the low byte (see Table 3-5). Setpoint commands return
batch status in the low byte of the status word and the setpoint number in the high
byte.
Word
Description
Word 1
Command number
Word 2
Status
Word 3
Value (MSW)
Word 4
Value (LSW)
Table 3-3. Input Data Format
Word 2
Bit
Indicator Status Data
Value=0
Value=1
00
Error **
(see See “Bit-0 Errors” on
page 13.)
No error
01
Tare not entered
Tare entered
02
Not center of zero
Center of zero
03
Weight invalid
Weight OK
04
Standstill
In motion
05
Primary units
Other units
06
Tare not acquired
Tare acquired
07
Gross weight
Net weight
08
Channel number
Least significant bit first.
09
10
11
12
13
Not used
14
Integer data
Floating point data
15
Positive weight
Negative weight
** This error condition does not necessarily mean the weight
being reported is invalid. Refer to the “Weight invalid” bit.
Table 3-4. Indicator Status Data Format
Note
Note