3 value, Value – Rice Lake 880 Performance Series Panel Mount Indicator/Controller - DeviceNet Interface Option Installation and Programming Manual User Manual
Page 17

Commands 13
Bit-0 Errors
• PLC command failed to execute.
• No configuration has taken place.
• Scale parameter is out of range.
• Print error has occurred.
• Load error has occurred.
• Memory error has occurred.
• Analog to digital converter error.
• Tare error.
• Scale over range error.
• Scale under range error.
• Non-recoverable configuration store error.
• Indicator in configuration mode.
3.2.3
Value
Weight data is returned to the master in the third and fourth words of the input
command format, depending on the command and the value type. The weight data
returned is the displayed weight after the command is executed, unless the command
specifies otherwise.
A negative value will be returned in the two’s compliment format.
Word 2
Bit
Batch Function Status Data
Value=0
Value=1
00
Digital input 4 OFF
Digital input 4 ON
01
Digital input 3 OFF
Digital input 3 ON
02
Digital input 2 OFF
Digital input 2 ON
03
Digital input 1 OFF
Digital input 1 ON
04
Batch not paused
Batch paused
05
Batch not running
Batch running
06
Batch not stopped
Batch stopped
07
Alarm OFF
Alarm ON
08
Setpoint number
09
10
11
12
13
Not used
14
Integer data
Floating point data
15
Positive weight
Negative weight
Table 3-5. Batch Function Status Data Format