5 c1 mode – country no. setting, 1 country no. table – Rice Lake Ishida iPC-WP Portable Bench Scales User Manual
Page 14

11/32
IPC-WP Series Service Manual
2.4 Memory
Switch
Operation
Display
1. C mode / F mode status
2. Press the Memory Switch.
2.5
C1 Mode – Country No. Setting
2.5.1 Country
No.
Table
Country No.
Item
Data
Wei-
ght
Digit
Bit
1 2 3 4 5 6 7
JPN ASIA
USA
AUS
CAN
EU
0 0 0 0 0 0 0
Start
range
0: ±10%
1: ±2%
1
10
0
D0
0 0 0 0 1 0 0
Zero
point
mark
0: Lights on at true zero
1: Lights on at
Provisional zero
2 D1
1 0 0 0 1 0 0
Below true zero
indication
0: "___"
1: Negative value
4 D2
0 0 0 0 1 0 0
Cleaning tare weight
by pressing ZERO key
0: No
1: Yes
8 D3
0 0 1 0 0 0 1
Decimal point
Indicator
0: "."
1: ","
1
10
1
D4
0 0 0 1 0 0 0
Over-scale
indication
0: BLANK
1: "OL"
2 D5
0 0 0 0 1 0 0
Tare
subtraction
0 : Not possible
1: Possible
4 D6
0 0 0 0 0 1 1
Tare clear with ZERO
key
0
: Possible
1
: Not Possible
8 D7
0 0 0 0 0 0 0
Stabilized,
re-stabilized
frequency
0: 5 times.
1: 8 times.
1
10
2
D8
0 0 0 0 0 0 0
Re-stabilization
Starting range
0: 2 times over
1: 4 times over
2 D9
0 0 0 0 0 0 0
Stabilized/re-
stabilized range
0: 3 times
1: 5 times
4 D10
1 0 0 0 0 0 0
Section
adjustment
0: No
1: Yes (JAPAN)
8 D11
804 000 010 020 04E 080 090 ←Display of F mode Measurement Condition