6 c2 mode – scale no. and decimal point setting, 2 operation, 1 scale no.[ x1 ] table – Rice Lake Ishida iPC-WP Portable Bench Scales User Manual
Page 15: 2 decimal point indication [ x2 ] table

12/32
IPC-WP Series Service Manual
2.5.2 Operation
Operation
Display
1. Stating Test
2. Setup of Country No.
x
To select the No., use the [ * ] key
x
Example: ASIA=2
3. When the C2 mode is then required, press the TARE key.
x
When finishing, press the Memory Switch to record
the data to the memory, and enter the Ending Test
Mode.
2.6
C2 Mode – Scale No. and Decimal Point Setting
2.6.1 Scale No.[ X1 ] Table
X1
Specifications
A/D Counts
1
3kg (2g/1g)
Multi interval
30000 (20/10)
2
6kg (5g/2g)
Multi interval
30000 (25/10)
3
15kg (10g/5g)
Multi interval
30000 (20/10)
4
30kg (20g/10g)
Multi interval
30000 (20/10)
5
3kg (1g)
Single range
30000 (10)
6
6kg (2g)
Single range
30000 (10)
7
15kg (5g)
Single range
30000 (10)
8
30kg (10g)
Single range
30000 (10)
9
6lb (0.005lb/0.002lb) / 3kg (2g/1g)
Multi interval lb/kg
30000 (25/10) / 30000 (20/10)
A
15lb (0.01lb/0.005lb) / 6kg (5g/2g)
Multi interval lb/kg
30000 (20/10) / 30000 (25/10)
B
30lb (0.02lb/0.01lb) / 15kg (10g/5g)
Multi interval lb/kg
30000(20/10) / 30000 (20/10)
C
60lb (0.05lb/0.02lb) / 30kg (20g/10g)
Multi interval lb/kg
30000(25/10) / 30000 (20/10)
D
100oz (0.1oz/0.05oz)
Multi interval oz
20000 (20/10)
2.6.2 Decimal Point Indication [ X2 ] Table
X2
Display
1
"0"
2
"0.0"
3
"0.00"
4
"0.000"