Chapter 4 maintenance, 1 disassembly procedure – Rice Lake Ishida iPC-WP Portable Bench Scales User Manual
Page 28

25/32
IPC-WP Series Service Manual
Chapter 4 Maintenance
4.1 Disassembly
Procedure
Note
The seal restricts the peel according to the country by a no report and doing as
wanting put it. Follow the relevant procedure for the respective countries.
Caution
The water proof sheet is to maintain the water proofing property. When you remove
the sheet, replace it with a new one.
4.1.1 Case
Disassembly Procedure
&
Assembly Procedure
1. When using dry batteries, remove them before
disassembly or assembly.
When using an AC adaptor, disconnect it before
disassembly or assembly.
2. Remove the weighing platter.
3. Remove the Water proof sheet attached to the
platter bracket.
Caution
When re-assembling the scale, use a new Sheet
protect.
When affixing the new sheet protect, completely
remove the starch left on the bracket.
Otherwise, the water proofing property will be
deteriorated.
4. Remove the 12 M4 nuts.
5. Remove the 4 M4 screws, then remove the
platter bracket.
Platter
Sheet protect
Platter bracket
M4 Nut
M4 Screw
Platter bracket