Smart Power Systems HR-110 User Manual

Page 24

Advertising
background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 23 of 53

WARNING:


To ensure proper voltage regulation, during the operation of generator system, the
load difference between Phase A and Phase B must never exceed 20%. Damage to
generator system caused by operating it with an unbalance load will void the
system’s warranty.

Wiring of the A.C. modular generator system and electrical distribution throughout
the vehicle must be done in accordance with applicable sections in the National Fire
Protection Association’s document NFPA 1901, the National Electrical Code

®

and/or

other applicable, recognized electrical code and by a certified electrician.

Smart Power

®

Systems’ A.C. modular generators are supplied with the neutral

bonded to ground. Refer to National Fire Protection Association’s document NFPA
1901, National Electrical Code

, and/or other applicable recognized electrical codes

before wiring an SPS A.C. modular generator system.

Never wire any loads to the generator’s output without a circuit breaker in series
with the load. Damage to the generator, to the components within that circuit,
electrical shock, or fire may result if a short occurs in an unprotected circuit. Run
all 120 VAC and 240 VAC electrical connections between the generator and the
distribution panel in conduit. Bypassing the SPS factory installed breaker will void
the system’s warranty. Replacement breakers must be obtained from Smart Power

®

Systems approved sources only.

Do not perform any wiring installations or modifications while the system is
operating. The A.C. modular generator system will generate enough voltage to
produce a fatal shock.

Never touch any live connections while the system is operating.

9.

Connect 12 VDC (vehicle battery positive) to the generator’s system controller input
(reference Figure 2). Connect the RED wire from the system controller, marked
“Vehicle +12V supply” to the vehicle’s ignition circuit through a 30 amp fuse.
Connect the BLACK wire to the vehicle’s ground (vehicle battery negative).

WARNING:


12 volts DC must be directly applied to the generator system controller whenever
the hydraulic pump is engaged. Failure to do so may cause excessive fluid
temperature, damaging the system components and will void the warranty.

Never come near a running fan with loose items such as long hair, clothing, jewelry,
ties, items that can fall out of pockets, etc.

Advertising
This manual is related to the following products: