Page 22 of 53

conduit to length without cutting the wire insulation. A conduit connector has been
provided to connect the conduit to the breaker panel. Connect the (4) four
generator output wires to the breaker panel as follows (see Figure 2 for electrical
schematic and wiring diagram):


Phase A:

Black wire (120 VAC)

Phase B:

Red wire (120 VAC)

Neutral:

White

wire

Ground:

Green

wire


To completely utilize the generator’s output capabilities, the 120 VAC loads must be
equally divided between the generator’s two main windings. Before wiring the
vehicle, calculate the wattage of each 120 VAC load that will be connected to the
generator. Next, create two groups of loads based on total wattage (add the
individual wattage of each load together). Exchange loads between the two groups
until the total wattage of the two groups is as close as possible to being equal. Wire
the system with one group connected to Phase A (BLACK) and neutral, with the
other group connected to Phase B (RED) and neutral.

ALTERNATE CONFIGURATION: 120 VAC only: If the application requires 120
VAC only, the generator terminal strip should be configured as depicted below. This
method ensures balanced loading of the generator, fully optimizing the system’s
capabilities. Make the following wire connections at the terminal strip:

a) place one jumper between wire 1 and wire 3.
b) place the second jumper between wire 2 and wire 4.
c) connect the phase wire from the breaker box to either wire 1 or wire 3.
d) connect the neutral wire from the breaker box to either wire 2 or wire 4.
e) connect the ground wire from the breaker box to the green wire.