Tjernlund SS1R SideShot (Discontinued Version - Pre UC1 Universal Control) 8504046 Rev 05/95 User Manual

Page 7

Advertising
background image

INSTALLATION

Tools required:

• Reciprocating Saw

• 1/2", 7/16",5/8" Wrench

• Drill and 1/8", 1/4", 1/2" Bits, 1” hole saw

• 1/4" Masonry Drill Bit

• Blade Screwdriver

• 1/4", 5/16”, 11/32" Nut Driver or Socket

• Wire Cutter/Stripper

• Hammer

• Tube Cutter

INSTALLING VENT HOOD TERMINUS

1. a) Fold template A along dashed line and attach in between the floor joists ensuring that it is snug against the sill plate and right

hand floor joist. Follow same procedure if floor trusses are used, (See Diagram B).

b) If the SS1-R is not being installed between floor joists, attach the template to the wall it will be exiting ensuring it is level.

2. Using 1/2" bit, drill pilot holes noted on each side of the template from inside through rim-joist, wall board, siding, etc., keeping

drill bit perpendicular to the wall. 1/2" bit must be long enough to penetrate through exterior.

3. Remove template from rim-joist and attach to building exterior, aligning pilot hole markings on template with holes previously

created in Step #2.

4. Drill the four corner holes noted on the template through the building exterior. Remove the template and mark lines from the

outside edge of the holes drilled, forming a rectangle.

5. Using reciprocating saw and appropriate blade, cut a rectangular opening through the rim joist, wall board, siding, etc., on the

lines marked in step 4. The rectangular opening should be no larger than 8-3/8" in width by 8" in height, (See Diagram C).

6. Knock out block material exposing rectangular opening through the wall.

7. Apply two beads of exterior rated caulk approximately 3/8" in width at the seam of the outermost casing of the Vent Hood and

the inner flange of the Vent Hood Terminus, (See Diagram D).