Tjernlund SS1R SideShot (Discontinued Version - Pre UC1 Universal Control) 8504046 Rev 05/95 User Manual

Page 8

Advertising
background image

7

8. Slide the Vent Hood through the wall while taking care installing the rain shield as shown, (See Diagram E). The nuts located on

the Vent Hood outermost casing should be facing up when sliding it through the wall. Mount Vent Hood to the exterior using
four #8 x 3" wood screws and spacers provided, (See Diagram E). Wall anchors are provided for installation into masonry
wall.

9. Connect the Plenum to the Vent Hood of the SS1-R following the steps on pages 7, 8 and 9.

10. After the SS1-R is completely installed, apply a bead of exterior rated caulk between the Vent Hood Terminus inner

flange and the exterior of the building, (See Diagram F).

INSTALLING PLENUM

Depending on building construction, it may be
necessary to notch out a section of the floor
joist to provide proper clearance for the SS1-R
motor, (See Diagram G).

1. Attach Template B to the floor joist that is to

be notched, aligning the sight line noted on
the template with the end or the outside
casing of the vent hood.

2. Cut out notch on line shown on the template.

DIAGRAM E

RAINSHIELD
(INSTALL BETWEEN BUILDING
EXTERIOR AND INNER FLANGE

BUILDING
EXTERIOR

OUTERMOST CASING

DIAGRAM D

DIAGRAM F

TERMINUS INTERIOR FLANGE

BUILDING
EXTERIOR

INNER FLANGE OF VENT

DIAGRAM G

IMPORTANT: DO NOT NOTCH ANY
OTHER JOISTS OTHER THAN THOSE
OUTLINED IN THESE INSTRUCTIONS

Advertising