INSTALLER NOTES

1. The installer must read and follow these instructions carefully to assure proper installation and operation of the water

heater vent package.

2. The installer must fill in the required information on the nameplate located on the Power Venter electrical box.

3. The installer must affix the wiring diagram label included with these instructions to the water heater casing adjacent to

its rating plate.

4. The water heater may only be installed on the suction side of Power Venter.

5. The installer must notify the owner of the maintenance (Page 13) required with the use of this product.

6. The installer must verify that the pilot safety controls on water heater are in good operating condition before

installation of the water heater vent package.

7. The Power Venter must not be installed into any portion of a vent system which serves appliances other than the

one(s) vented by the VP-2F or VP-3F.

SEQUENCE OF OPERATION

1. Water heater thermostat calls for heat.

2. Simultaneously, the Power Venter is actuated by the gas pressure switch and the burner fires.

3. When the thermostat is satisfied the burner shuts down.

4. The Power Venter continues to operate for a non-adjustable time period of approximately 45 seconds to purge the

vent system of residual flue gases.

5. If, at any time, sustained flue gas spillage is detected by the Linear Limit spillage sensing switch the pilot / ECO circuit

is de-energized, disrupting the flow of gas to the burner and pilot. The reset button on the Linear Limit will need to be
pushed in and the pilot will need to be relit to establish water heater operation.

TYPICAL INSTALLATION

2

WITH THE ECO OF THE WATER HEATER.

REQUIRED. WIRE THE LINEAR LIMIT IN SERIES

THE THERMOCOUPLE JUNCTION ADAPTER IS NOT

ON 750 MILLIVOLT (POWER PILE) HEATERS

THERMOCOUPLE JUNCTION ADAPTER

PRESSURE TAP

FROM THERMOSTAT

6' LINEAR
LIMIT LEADS

115/1/60

NAMEPLATE

MOTOR

VENTER

POWER

SWITCH

GAS PRESSURE

GAS PRESSURE SWITCH

ALUMINUM TUBING TO

24" LONG 1/4" O.D.

LINE

GAS SUPPLY

BY OTHERS

WATER HEATER

BY OTHERS

THERMOSTAT

LINE

GAS PILOT

8050013 11/30/11

CLIPS

ROUTING

CABLE

THERMOSTAT CABLE

2 WIRE JACKETED

POWER

6 FOOT

BY OTHERS

FLUE PIPE

SWITCH SET AT 185°F

SPILLAGE SENSING

LINEAR LIMIT

GAS PRESSURE

TAP PORT

NOTE:

CORD

TJERNLUND
VENT HOOD

NOTE: The installer must install the Power

Venter downstream of the draft hood.