Model – Tjernlund VSUB Series Universal Blowers for Combustion Air or Draft  8504114 User Manual

Page 2

Advertising
background image

TABLE OF CONTENTS

PAGE(S)

VSUB BLOWER DESCRIPTION ................................................................................................................................. 1

DIMENSIONS AND SPECIFICATIONS ........................................................................................................................ 1

VSUB FAN PERFORMANCE CURVES..........................................................................................................................2

INSTALLATION RESTRICTIONS & CAUTIONS ........................................................................................................... 3

ADDITIONAL REQUIREMENTS BASED ON DRAFT INDUCER OR COMBUSTION AIR APPLICATION ............... 3-4

DRAFT INDUCER TERMINATION CLEARANCES FOR CANADIAN & U.S. INSTALLATIONS ............................... 4-6

COMBUSTION AIR INTAKE CLEARANCES ................................................................................................................ 6

COMBUSTION AIR INTAKE HOOD/LOUVER OPENING SIZING............................................................................. 6-7

VSUB INSTALLATION ............................................................................................................................................... 7-8

PSA-1 FAN PROVING SWITCH INSTALLATION ...................................................................................................... 8-9

WIRING .....................................................................................................................................................................9-11

PSA-1 SAFETY INTERLOCK AND DRAFT ADJUSTMENT SET-UP PROCEDURE..............................................12-13

SAFETY INTERLOCK TEST.........................................................................................................................................13

COMBUSTION AIR ...................................................................................................................................................... 13

MAINTENANCE, SERVICE & HOUSING ROTATION .............................................................................................13-14

HOW TO OBTAIN SERVICE & LIMITED WARRANTY ..........................................................................................14-15

REPLACEMENT PARTS ..............................................................................................................................................15

Tjernlund Products welcomes your comments and questions. Call us at 800-255-4208, Fax 651-426-9547, Email us at
[email protected] or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794.

VSUB-SERIES UNIVERSAL BLOWER DESCRIPTION

The VSUB-Series Universal Blowers are a multi-purpose adjustable-fixed speed or automatic-variable speed blower. It can vent natur-
al gas, LP-gas and oil fired heating appliances, clothes dryers or be used as a utility blower that will handle up to 575° F. It can also
be used as a adjustable-fixed speed or as an automatic-variable speed combustion air intake blower. All models are supplied with the
model PSA-1 Fan Proving Switch which will disable the burner(s) if an exhaust/supply malfunction should occur, and a FFP-1 fire
/freeze limit that will shut the VSUB Blower off in the event of extreme temperature swings for combustion air applications. The VSUB
Blower is rated for indoor or outdoor installation. Use positive pressure rated vent on the discharge side of the blower when venting
flue gases and mounting indoors. Refer to heating appliance manufacturer's instructions regarding specific venting requirements.

DIMENSIONS AND SPECIFICATIONS

1

3x230/460

2875

1.6

66

7 7/8

5 1/4

16 1/2

28 1/2

14 1/2

10 1/4

2125

3.2

153

11 7/8

9 5/8

21 1/2

33

17 3/8

13

2115

6.0

218

15 7/8

12

27 3/4

42 3/8

23 1/4

16

1760

8.8

319

19 7/8

14 1/2

32 3/4

44 3/4

26 1/2

23 1/4

Yes with

VFD

VSUB8

VSUB12

VSUB16

VSUB20

Does not include Amp load of VFD Drive.

in

in

in

in

in

in

lbs

@ 208 V

VAC

A

C

E

G

I

K

Dimensions

Weight

Full Speed

Max RPM with VFD

Voltage

MODEL

Variable Speed Motor

Figure 8067001 3/3/04

Power Rating

hp

1/3

1

3

2

L

J

H

in

18 1/2

in

in

15 1/2

30 1/2

22

35

18 7/8

F

D

B

in

in

7 7/8

7 5/8

in

10

10

11 7/8

12 1/2

25 1/2

28

46 3/4

26 3/4

24 3/4

44 3/8

14

14

19 3/4

15 7/8

13 1/4

14

M

O

N

8

in

in

in

23 1/2

13 3/8

9

28 1/2

15 1/2

19

43 3/4

23 1/2

15 3/8

34 3/4

18 7/8

3x230/460

3x230/460

3x230/460

@ 460 V

0.8

1.5

2.8

4.1

Yes with

VFD

Yes with

VFD

Yes with

VFD

5.6

@ 230 V

1.5

3.0

8.2

Amps

*

*

O

L

END VIEW

M

N

K

MOUNTING

LOCATION (4)

D

TOP VIEW

B

ØA

ØF

E

C

G

H

I

J

INCLUDED SQUARE

TO ROUND ADAPTER

Advertising