Tjernlund VSUB Series Universal Blowers for Combustion Air or Draft  8504114 User Manual

Page 3

Advertising
background image

COMPLETE VSUB-SERIES UNIVERSAL BLOWER SYSTEM SOLUTIONS

This installation manual does not contain any vent system design documentation. Installation and use of Tjernlund controls like the
CPC-2 Constant Pressure Controller, VFD Series Variable Frequency Drives, EXP-4 Appliance Interlock Expansion boards, UC-1
Universal Control or MAC1E and MAC4E Multiple Appliance Controls are not covered by this manual. Please refer to those installa-
tion manuals for details.

VSUB-SERIES FAN PERFORMANCE CURVES

VSUB Blower performance was independently tested by an accredited AMCA certified testing facility.

Selection of a VSUB Blower as a Draft Inducer involves determination of the maximum volume of gas to be handled, the density of
the gas and the maximum static pressure which the fan must overcome. Using the VSUB Blower as a combustion air intake or com-
mercial clothes dryer vent blower, involves the determination of the maximum volume of air to be handled and the maximum static
pressure which the fan must overcome.

Variable speed VSUB Blowers can operate at virtually any point to the left of the performance curve. For sidewall termination applica-
tions add 0.60" W.C. to vent system resistance to accommodate the effects of wind loading.

Consideration must be given to the temperature of the gases being handled and the elevation above sea level of the installation when
selecting a VSUB Blower. Blower performance curves are based on standard air conditions @ sea level.

Please feel free to contact us for application and model selection assistance by calling 800-255-4208 or email us at
[email protected]. Vent layout or other information can be faxed to 651-426-9547.

2

0

0

CFM (STD AIR 70 DEGREES F)

STATI

C

PRESSURE

I

N

W.

C.

0

0

100

200

300

400

500

600

700

800

900

1000

1000

900

800

700

600

500

400

300

200

100

0.5

1

1.5

2

2.5

3

3.5

4

4

3.5

3

2.5

2

1.5

1

0.5

VSUB8 PERFORMANCE

3

2.5

2

1.5

1

0.5

0

0

500

1000

1500

2000

2500

CFM (STD AIR 70 DEGREES F)

STATI

C

PRESSURE

I

N

W.

C.

0

0

0.5

1

1.5

2

2.5

3

VSUB12 PERFORMANCE

2500

2000

1500

1000

500

4.5

4

3.5

3

2.5

2

1.5

1

0.5

0

0

500

1000

1500

2000

2500

3000

3500

4000

4500

CFM (STD AIR 70 DEGREES F)

STATI

C

PRESSURE

I

N

W.

C.

0

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

4500

4000

3500

3000

2500

2000

1500

1000

500

VSUB16 PERFORMANCE

4.5

4

3.5

3

2.5

2

1.5

1

0.5

0

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

5500

6000

CFM (STD AIR 70 DEGREES F)

STATI

C

PRESSURE

I

N

W.

C.

6000

5500

5000

4500

4000

3500

3000

2500

2000

1500

1000

500

0

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

VSUB20 PERFORMANCE

Advertising