Initial Start-Up

When power is applied to the unit, the control will

briefly display all symbols, and the Compressor

symbol will be displayed (if unit is calling for cooling).

There may be a brief delay prior to the evaporator and

condenser fans turning on. When the evaporator and

condenser fans are activated the “FAN” symbol will

turn on.

Normal Unit Cycle

After the bottle probe has reached the set point (all

units are shipped with the set point of 55°F and a dif-

ferential of 1°F), the unit will turn off. The WhisperKOOL

Humidity Management (WHM) is an adjustable feature

which allows the customer the convenience of man-

aging the humidity enhancement of their wine cellar.

The WHM is one of the many Customer Preference Se-

lection features which allow the customer the ability

to fine tune the controls. Feature is off from the factory

but can be turned on with the “FON” parameter.

Anti Short Cycle

The Anti Short Cycle ensures that the compressor will

remain off for a period of 3 minutes after the unit

has reached the set point to allow the pressure in

the refrigeration unit to equalize prior to starting the

compressor.

Anti Frost Cycle

The Anti Frost Cycle is a precautionary measure, as

icing or frosting of the coil does not occur during nor-

mal operation. The unit will go through an anti frost

cycle when the evaporator temperature reaches 26°.

During the Anti Frost cycle, the unit will stop cooling

and run the indoor fan to provide air flow across the

indoor coil, which will melt any frost accumulation.

Bottle Probe Failure Protection

In the event that a bottle probe should fail, the APST

(Advance Product Safety Technology) will automati-

cally transition the Refrigeration Compressor cycles

to a pre-determined time series (based on detailed

laboratory testing), which will ensure that the product

is kept within the safe range.

Remote Control (optional)

The control panel can be installed or mounted sepa-

rately from the cooling unit itself (remotely), using the

supplied cable. This option provides unique flexibility

for installing the Extreme Series cooling unit in your

wine cellar. The remote option must be specified when

the unit is ordered.

Note: Remote Control is generally standard with a

“Ducted Unit”.

Ducting and Ventilation Options

The ventilation system is ideal for ducting. The option-

al collars fit standard ventilation ducting allowing the

installer to vent air to and from the unit for optimum

performance (please see specifications for details).

Unit OPERATION: