Installation – Vintage Cellars Slimline 2500 User Manual
Page 15

www.whisperkool.com | Page 13
STEP 7
Slide the cooling unit in from the cellar side
with the thermostat facing inside. Secure the 2
Brackets to the wall through the pre drilled holes.
The screws should penetrate the studs and/or
frame. Seal all cracks and gaps around the unit
with an air-tight sealant or caulking to prevent air
leakage.
Note: If you use decorative molding, it should be
attached to the walls and never to the cooling unit.
STEP 8
Attach the condensate drain line
The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location.
It is important that the drain line tube is properly connected and used to prevent leakage and other problems
associated with excess condensation.
Failure to use the condensation drain line tube will void the warranty on the unit.
Note: To prevent mold from growing, allow the drain line to
hang above the water line.
Failure to install the drain line voids warranty.
To prevent mold from growing, allow the drain line to
hang above the water line.
STEP 9
If removed, install the grille’s on both sides of the unit and plug in the power cord. The use of an extension cord is not
recommended.
Drain line is
above possible
water level
INSTALLATION
CELLAR SIDE
Bottle Probe
Power
Drain line
WRONG: Drain line
is under water.