Initial Start-Up

When power is applied to the unit, the control will

briefly display all symbols, and the Compressor

symbol will be displayed (if unit is calling for cooling).

There may be a brief delay prior to the evaporator

and condenser fans turning on.

Normal System Cycle

After the bottle probe has reached the set point

(all units are shipped with the set point of 55°F and

a differential of 1°F) the unit turns off. The WHM is

an adjustable feature which allows the customer

the convenience of managing the humidity

enhancement of their wine cellar. The WHM is one

of the many Customer Preference Selection features

which allow the customer the ability to fine tune the

controls. This feature is set to 0 when shipped but if

needed can be adjusted.

Anti Short Cycle

The Anti Short Cycle ensures that the unit will remain

off for a period of 3 minutes after the unit has reached

the set point to allow the pressure in the refrigeration

system to equalize prior to starting the compressor.

Anti Frost Cycle

The Anti Frost Cycle is a precautionary measure, as

icing or frosting of the coil does not occur during

normal operation. The system will go through an

anti frost cycle when the evaporator temperature

reaches 26°. During the Anti Frost cycle, the unit will

stop cooling and run the indoor fan to provide air

flow across the indoor coil, which will melt any frost

accumulation.

Bottle Probe Failure Protection

In the event that a bottle probe should fail, the

APST (Advance Product Safety Technology) will

automatically transition the Refrigeration Compressor

cycles to a pre-determined time series (based on

detailed laboratory testing), which will ensure that

the product is kept within the safe range.