DRAIN LINE PUMP SYSTEM

1. Drain pan fills with water which flows into reservoir. Intake hose between reservoir and pump is empty (filled with

air).

2. Raising water lifts float, activating pump, which self primes by drawing water up from reservoir. During this period

the pump is operating hot and dry and will click loudly. Once the air in the intake hose has been purged, water

entering the pump cools and lubricates it so that the clicking noise becomes a low hum. Water flows through the

pump and out of the discharge hose.

3. Water level in the reservoir has now receded enough to lower the float, deactivating the pump. However, the

weight of the water in the discharge hose plus atmospheric pressure at the drain pan outlet forces the water

remaining in the intake hose to continue flowing out through the pump until the reservoir, intake hose, pump and

discharge hose are completely empty, at which point the siphoning stops.

4. As the evaporator produces more condensate, the drain pan again fills up with water which flows into the reservoir.

Since the intake hose is filled with air again, the cycle repeats itself.

RESULT: EVERY TIME THE PUMP

RUNS HOT AND DRY, IT SUSTAINS

A SMALL AMOUNT OF DAMAGE

WHICH CAUSES PREMATURE WEAR.

THE NEXT TIME THE PUMP STARTS

UP DRY, IT MAY RUN FOR 11

SECONDS BEFORE IT COOLS DOWN

THE NEXT TIME 12 SECONDS

AND SO ON. ALSO WHILE THIS IS

OCCURRING, THE PUMP IS CLICKING

LOUDLY. THIS IS ACCEPTABLE

DURING THE INITIAL START UP

PHASE, BUT NOT ACCEPTABLE

DURING SUBSEQUENT OPERATIONS

OF THE PUMP.

WHEN YOU CONSIDER THAT

THIS WILL OCCUR A NUMBER

OF TIMES EVERY DAY OF THE

COOLING SEASON IT IS EASY

TO SEE THAT THE DAMAGE WILL

RAPIDLY ACCUMULATE. IF THE

PUMP IS ALLOWED OPERATE IN

THIS CONDITION REPEATEDLY, THE

NOISY PERIOD WILL GET LONGER

AND LONGER OVER THE COOLING

SEASON UNTIL THE CUSTOMER

COMPLAINS OR THE PUMP

EVENTUALLY FAILS.

THIS CAN EASILY BE AVOIDED

BY INSTALLING THE DISCHARGE

HOSING CORRECTLY WITH AN

ANTI-SIPHON DEVICE WHICH WILL

EQUALIZE THE ATMOSPHERIC

PRESSURE AND ELIMINATE THE

SIPHONING.

INCORRECT:

Failure to follow correct Discharge Hose installation will damage pump.

4

3

1

2

DRAIN PAN

DRAIN PAN

DRAIN PAN

DRAIN PAN

PUMP

PUMP

PUMP

PUMP

BREATHER TUBE

BREATHER TUBE

BREATHER TUBE

BREATHER TUBE

RESERVOIR

RESERVOIR

RESERVOIR

RESERVOIR

ATMOSPHERE

PRESSURE