Custom Duct Work

Another Option that might be considered is building Insulated Custom Duct Work. Figure 6 below is an example

that may be followed to create Insulated Custom Duct Work to extend to the attic using 1/2” Plywood, 1/2” Insulation

Board and (24) Angle Brackets.

Ducting Information

When Ducting the Exhaust away from the Cooling Unit, custom Ducting will be sufficient if it follows these

recommendations:

Custom Ducting is insulated so that the warm exhaust air in the duct does not affect the air in the Cellar.

The surface area of inside the duct is greater than or equal to 51 sq. in.

The Duct Work follows the General Duct Recommendations on page 21.

Measure the space between the

cooling unit and the wall and add

the distance to these dimensions for

the total length.