6.2

free-d

calibration wizard

Run the program freed_v14.exe. This is a menu-driven program with three
main windows.


6.2.1 Studio list

Select: View

Studio List (Alt-V-S)


Enter a four-character name for the studio. This name is arbitrary and can be
displayed on the Free-d processor display unit to check if the correct database
is being used for the studio.

Enter the studio ID number (in hexadecimal). The

free-d

processor can store

up to 256 different target databases (ie, up to 256 different studios). 0-255 in
decimal equates to 00-FF in hexadecimal. If only one studio is to be calibrated
it is advisable to enter studio ID as 00-FF. This will upload the calibrated
database to all addresses in the database.

If

two

studios are

equipped with

free-d

targets then addresses
00-7F and 80-FF could
be used. Use switch
S3 on the front of the
processor

card

to

increment

or

decrement the current
studio

database

address. Please note
that when changing
from

one

target

database to another, the displayed studio name can change instantly, but the
actual system memory can take up to 5 minutes to reconfigure. If the current