The DSP status is a signed 8-bit number which when negative indicates an
error condition as follows:


-1

Too few valid targets visible to compute camera position.

-2

Iteration failed to converge.

-3

A DSP reset occurred.

-4

Internal DSP error.

A zero or positive value of DSP status indicates the number of iterations which
were required to compute the camera's position.


A.3.4 Type D3 - control parameters

The D3 message is used for transferring the control parameters. It may be
sent to the

free-d

unit in order to set their values, or requested from the

free-d

unit in order to interrogate the current values. Operation of switch S4 saves
the current values to EEPROM, which become the default values following a
subsequent processor reset.


The message contains 13 bytes as follows:


<D3>

Message type

<CA>

Camera ID

<SN>

Studio ID

<SM>

Smoothing value

<HI>

Maximum asymmetry

<HO>

Half box width

<BT>

Black video threshold

<WT>

White video threshold

<BC>

Black video clip level

<WC>

White video clip level

<MB>

Maximum number of >black pixels between boxes

<MW>

Minimum number of >white pixels in inner box

<CK>

Checksum

The ‘studio ID’ is in the range 0 to 255 and determines which database of
target positions (stored in the on-board EEPROM) is used.

The ‘smoothing value’ is in the range 0 to 255, corresponding to settings of
smoothing between 0.000 and 0.996.

The ‘maximum asymmetry’ is in the range 0 to 255, in units of 1/128 pixels.
This sets a limit on the difference between the centre position of a target as
measured by the hardware and its position as estimated as the mid-point
between opposite edges.