Ethernet connection, Cable clamp, Emergency stop – Vinten Radamec Fusion FBH-175 User Manual

Page 19: Setting the height drive number, System configuration port

Advertising
background image

18

The height drive will then automatically move the column repeatedly over its stroke to establish
limits of travel.

8. Once movement has ceased, select OK (23) to close the ‘Set Pan, Tilt & Height Limits’ form (Fig 3).

9. Select OK (21) to close the main screen (Fig 2).

10. Disconnect the USB lead from the system configuration port and replace the cover (15).

Ethernet connection

The studio ethernet cable connects to the EPL in port (8) from the VRC system. The head communication cable
connects from the Fusion head to the EPL out port (7).

Cable clamp

All cables can be fed through and secured using the cable clamp (13) to keep the system tidy and prevent con-
nectors/ports being damaged if a cable becomes snagged.

Emergency stop

If the emergency stop button is depressed (16), power to the Fusion FBH-175 height drive is immediately dis-
connected. This loss of power will also affect the Fusion head connected to the head power output socket (11).

To reset the emergency stop, twist and lift the stop button (16). Power will immediately be reinstated, but the
height drive will need re-initialising by the Vinten Radamec Control System (refer to the Vinten Radamec Con-
trol System Operators Guide for further detail, Publication No. V4009-4980).

Setting the height drive number

Each Fusion unit in a system is uniquely identified so that when a camera channel is selected on the control
panel, communication is established with the correct channel. This identification is configured at the factory,
but may be re-assigned later if required. The drive identification setting switch is located beneath the a cover
(14). Please refer the Fusion FBH-175 Height Drive Maintenance Manual (Publication Part No. V4031-4990)
for further detail.

System configuration port

The USB system configuration port is located beneath a cover (15), and allows external connection to config-
uration software tools. For more information refer to Learn height stroke length on page 16 and the Fusion
FBH-175 Height Drive Maintenance Manual (Publication Part No. V4031-4990).

WARNING! The emergency stop button (16) has no effect on devices connected to the

auxiliary power socket (12). Only connect ‘non-moving’ devices to this port.

Advertising