- 16 -

Fig. 5 Temperature Controller (4.25”L X 3.75D X 4.25”H)

Parts included:

Packaged Cooling system
Temperature Controller (4.5”LX4.5”WX3.75”D) + Air Probe

Parts not included:

Insulated ducts

CAUTION:
Low ambient condition kit is required if the installation area will be below
50°F.

2. Location

• Place the unit in a properly ventilated location. If it is not, heat exhausted by

the condensing unit will build up and the cooling system will not operate
properly.

• Cooling unit shall be elevated to avoid possible flooding and shaded from

direct sun. It shall not be exposed to temperatures higher than 110 °F or
lower than 50 °F.

• Leave minimum 5 feet clearance for hot air exhaust and leave minimum 1 foot

clearance for the ambient fresh air intake.

• Supply air flow shall be unobstructed for minimum 12” for a direct blow

installation; leave 2” clearance for a deflector installation; return air shall be
unobstructed for minimum 6”.

• Overall cold –air supply and room-air return duct length can be up to 50 ft

long; overall hot-air exhaust and ambient-air intake duct length can be up to
50 ft long.

• Secure the ducts with conduits to the cellar exterior walls and make sure they

are not curled, twisted, bent and clogged.