to the perimeter location of the boundary wire. Make sure that
the wire length is adequate to route wire along the outside
wall and bury before cutting. Splice the ends of the twisted

wire to the ends of the boundary with the supplied waterproof
splices.

WARNING: Use only the waterproof splices (approved for
direct burial) supplied with this system. If additional splices
are required, they may be purchased from Innotek. Using
non-waterproof electrical tape, solder, or twisted wire nuts will
cause an intermittent signal or disable the system. The water-
proof splices included in your containment system are
designed to provide a sealed connection between the wires.

Waterproof Splices–Your containment system
includes one of two different styles of waterproof
splices that are designed to provide a sealed connec-
tion between the wires. Refer to the following illustra-
tions to identify the splices included with your system.

Gel-Filled Capsule Splice–To use the gel-filled cap-

s u l e
splice,
s t r i p
5 / 8
inch of
insula-
t i o n
f r o m
t h e
e n d s

of the wires you are joining.
With the ends of the wires even
and together, place the wire
nut over the wire ends and turn
the wire nut clockwise until it is
securely fastened. Snap open
the hinged lid of the gel-filled
capsule and insert the wire nut

as deeply as possible into the waterproof gel. Snap
the lid shut, making sure the wires exit the splice on
either side. Tie a knot in the wires as shown in the
diagram to prevent them from pulling out of the gel-
filled capsule when the wire is buried.

Black Cap Splice–To use the black cap splice, a sin-
gle boundary wire is placed into one of the three holes
of the spliced. The insulation on the boundary wire
should not be stripped before placing wire into the
holes. The other single boundary wire is placed into
one of the other holes. That leaves one extra hole that
is not used. A pair of pliers should be used to press
down on the top black part of the splice.

3. Plugging in the Power Adapter - Make sure the POWER
switch on the transmitter is in the OFF position. Plug the AC
power adapter into a nearby 110-volt household outlet. Plug
the other end of the power adapter into the power jack
(labeled PWR) on the transmitter. Place the power cord wire
under the wire retention tab on the housing.

4. Checking Out the Installation - Make sure your dog is not
wearing the collar and no one is touching the collar probes.
Slide the transmitter POWER switch to the ON position. A
green indicator light should illuminate on the transmitter indi-
cating a properly connected boundary loop. If the green indi-
cator light does not illuminate, refer to the transmitter prob-
lems table in the Troubleshooting Section (Section 8 pg 17).

5. Proceed to Section H, Testing the System - All
Systems.

G. Final Connection–SD-2200 ONLY

After the transmitter has been installed on the wall and the
boundary wire in place, the final connections must be made.

11.

INSTALLATION

Gel-filled capsule splice

Black cap splice

Gel filled
capsule

Wire

Wire nut

Wire