Petsafe Innotek Smart Dog® Rechargeable In-Ground Pet Fencing System User Manual

Page 19

Advertising
background image

Innotek, Inc. (800)-826-5527 www.innotek.net

5. Dog receives stimulations in the
safe part of the yard. (continued)

6. Dog receives stimulation inside
the home

Transmitter Problems:

1. Transmitter alarm is operating
and status light is flashing.

2. Transmitter status light indi-
cates the boundary wire is broken
or disconnected.

3. No status light on the transmit-
ter and alarm is silent.

4. No status light on the transmit-
ter and the alarm is on. (System
on battery backup power.)

4. Move large metal objects such as swing sets and trampolines
farther away from the boundary wire.

1. Remove the collar receiver when the dog enters the home.
2. Field width too wide.
3. Reposition the boundary wire farther from the house. See
Section 4.A page 7.
4. Place transmitter (and lightning protector, if applicable) away
from areas where the dog may be confined. A low level contain-
ment signal is radiated from these components and can cause the
collar receiver to function. Verify that the containment wire
remains tightly twisted at each component connection point.

Possible Solutions:

Check the status indication table located on transmitter and in
Section 1 page 5 to determine cause and corrective action.

1. Check boundary wire connections at transmitter (and lightning
protection module, if applicable) for proper connection.
2. Check for broken or damaged wires at outside entry into house.
3. Perform Transmitter Loop Test Procedure to locate and correct
the problem. See Test Procedures, page 20.
4. Perform Wire Break Location Test Procedure and correct the
problem. See Test Procedures, page 20.

1. Verify the transmitter POWER switch is ON.
2. Check that the adapter (and lightning protector, if applicable)
are plugged in properly.
3. If system is plugged into a GFCI outlet, check to see if the cir-
cuit has been tripped. Reset GFCI circuit if required.
4. Verify that the outlet is working properly by plugging in a known
working item such as a radio.
5. SD-2200 only. If the green power light on the lightning protector
is not illuminated, unplug the lightning protector and plug the
power adapter directly into the 110-volt outlet. If the transmitter
operates when bypassing the lightning protector, contact Innotek
for a warranty replacement lightning protector. Do not use the sys-
tem until a replacement lightning protector has been provided and
installed.
6. If possible, check the voltage of the power adapter using a digi-
tal multimeter. It should read greater than 24 volts AC.

1. Check that the adapter (and lightning protector, if applicable)
are plugged in properly.
2. If system is plugged into a GFCI outlet, check to see if the cir-
cuit has been tripped. Reset GFCI circuit if required.
3. Verify that the outlet is working properly by plugging in a known
working item such as a radio.

Dog Response Problems:

Possible Solutions:

19.

TROUBLESHOOT-

Advertising