Pilz PSEN op4B-S-3-080 User Manual
Page 32

PSEN op4B Series
Operating Manual
28
Abb. 22
6 FUNCTIONS
6.1 Selecting the operating mode via DIP switches
On the front of the receiver (RX) there is a cover flap (Fig. 22), which is
easy to open using a screwdriver and enables access to a row of DIP
switches for the following configurations:
-
Muting function/muting timeout
-
Feedback loop monitoring function
- Manual/automatic
reset
The device will not accept configuration
changes during normal operation. A
configuration change will only take effect
once the device is reset.
Particular care should therefore be taken
when setting the DIP switches.
DIP-sw FUNCTION
ON
OFF
1 Muting
timeout
10 min
Infinite
2 Muting
T-shape
configuration, linear
configuration
L-shape
configuration
3
Feedback loop
monitoring
Deactivated
Activated
4 Restart
Automatic
Manual
6.2 Standard configuration
The device is supplied with the following standard configuration:
- Muting
timeout: 10
min
- Muting: In
T
shape
configuration
-
Feedback loop monitoring function:
Deactivated
-
Restart:
Automatic
NOTE: The muting function can only be activated if muting inputs
1 and 2 and the muting lamps are connected correctly.
Detailed information on this function can be found in
chapters 6.3 and 6.4.
DIP SWITCHES