Scan_nlist, Scan_on – Axesstel PST User Manual
Page 97

AXESSTEL Software User's Guide
Contents
scan_mode
0=A R R R (all PNs), 1=A N N N (list).
incr
0=Use pilot_inc, 1,2...=User specified.
win_siz
0=Use (PN 64*Incr), 1= WinN, 2... 512=User specified.
Example
scan_config 0 3 1 2 0 0 0
Response
Resets PN scanning to scan all PN space using an increment of 3.
SCAN_NLIST
This command lets you load the Retriever Pilot Scanner with
Neighbor list information to either augment or override the OTA
Neighbor List, or to provide a pilot list for scanning PN offsets in List
mode.
Syntax
scan_nlist replace_all active_pn nlist_siz
{P1, P2,... P20}
replace_all
controls how Retriever uses this list. Use replace_all=1 to
completely replace the Neighbor list. Use replace_all=0 to append
the new list to the end of the existing Neighbor list. Retriever
supports up to 20 total pilots in Idle/Scan List mode.
active_pn
is the Active serving system’s PN to associate this list with
nlist_siz
is the length of the list being entered
P1
, P2, etc., is the list of pilot PNs to include in the Neighbor list.
Example 1
scan_nlist 0 160 2 {24,48}
Response
Pilots PN=24 and PN=48 are added to Active pilot PN=160’s
Neighbor List.
Example 2
scan_nlist 1 160 5 {4,16,32,96,104}
Response
Replaces any existing pilot list with PN offsets 4,16,32,96, and 104 for
scanning in List mode.
SCAN_ON
Starts PN scanning using either the default parameters or
parameters that have been entered using the scan_config command.
Syntax
scan_on
integ
0=256, 1=360, 2=512, 3=720, 4=1020.
ho_typ
0=Within Nlist only, 1=All, 2=None.
log_fmt
0=Dense Scanner format, 1=STD AXESSTEL DM format.
log_thr
0=All, 1=T_DROP, 2=T_ADD (STD log_fmt only).
Parameter Value
Script Command List
Example
scan_on
Response
PN scanning begins.
AXESSTEL Proprietary
97