3.8 CCITT V.35 Interface Model -35

This interface is compatible with CCITT recommendation V.35 Appendix II (electrical characteris-
tics for balanced double-current interchange circuits).

The RTS control input is biased to the OFF state. If a connection is not made to this line, the CTS
control output will drive to the OFF (negative voltage) state. Recommended cable is a twisted
multi-pair type with a characteristic impedance of 80-120 ohms at the operating data rate. The
balanced line receivers are terminated at 100 ohms.

The V.35 interface uses a standard 34-position, M-series (MRAC-34S) Winchester connector. The
terminal or computer interface must be configured as Data Terminal Equipment (DTE) for proper
communications handshake (refer to Table 3-J for pinouts).

NOTE: Only local controls are supported.

Table 3-J. CCITT V.35 Digital Interface and Pin Assignments

pin

mnem

signal name

CCITT

signal direction

a/b

A

FG

Frame Ground

101

n.a.

B

SG

Signal Ground

102

n.a.

C

RTS

Request To Send

105

to modem

D

CTS

Clear To Send

106

from modem

E

DSR

Data Set Ready

107

from modem

F

DCD

Data Carrier Detect

109

from modem

R/T

RXD

Receive Data

104

from modem

V/X

SCR

Serial Clock Receive

115

from modem

Y/AA

SCT

Serial Clock Transmit

114

from modem

P/S

TXD

Transmit Data

103

to modem

U/W

SCTE

External Transmit Clock 113

to modem

CC (*) RL/RT

Remote System Test

140

to modem

HH (*) LL/LT

Local Loopback Test

142

to modem

n.a. = not applicable
(*) = The 2270 Modem includes a built-in System Test feature. Two normal test lines (CCITT V.35 pins CC and
HH) are used for this interface loop. Refer to Chapter 5, "Troubleshooting," for a more thorough description of
this feature.