CANOGA PERKINS 3240S SNMP-Managed T1/E1 Fiber-Optic Multiplexer User Manual

Page 37

Advertising
background image

EdgeAccess

3240S Fiber-Optic Multiplexer

4-5

Start

Set Local mux to Local

loopback

Data

loops?

Set Local mux to

Remote loopback

Data

loops?

No

No

Connect fiber jumper between local Rx
and Tx, then set MODE switch to NOR

Data

loops?

No

Check received optical

power at local Rx

>/= lowest

power value?

Check transmitted optical

power at remote mux Tx

Check transmitted optical

power at local Tx

Tests local I/O ports
and most of Local mux

Tests Local mux, fiber, and all of
Remote mux except I/O ports

Tests Local mux, up to fiber

Replace local mux

Replace remote mux

Replace local mux

>/= lowest

power value?

Replace remote mux

Replace local Rx fiber

Values for lowest received power:
850 nm: -33 db
1310 nm HI pwr/1550 nm: -32 dB
1310 nm LO pwr: -24 dB

Values for lowest transmitted power:
850 nm: -21.5 +/-4 db
1310 nm HI pwr: -14 +/-2 dB
1310 nm LO pwr: -24 +/-2 dB
1550 nm: -32 +/-2 dB

>/= lowest

power value?

No

Replace local mux

Check received optical

power at remote Rx

>/= lowest

power value?

Values for lowest received power:
850 nm: -33 db
1310 nm HI pwr/1550 nm: -32 dB
1310 nm LO pwr: -24 dB

Values for lowest transmitted power:
850 nm: -21.5 +/-4 db
1310 nm HI pwr: -14 +/-2 dB
1310 nm LO pwr: -24 +/-2 dB
1550 nm: -32 +/-2 dB

Replace remote mux

Replace remote Rx fiber

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

Figure 9. Flowchart for Using Loopback in Troubleshooting