2 vt100 terminal screens, 2 vt100 terminal screens -2, Table 1. rj-45 8-pin modular pin out -2 – CANOGA PERKINS 2361 T1 Modem User Manual

Page 30

Advertising
background image

The EdgeAccess Universal Chassis System

2361 Modem Users Manual

4-2

Tab:

Press the Tab key to highlight a menu item one column to the right of the item
currently highlighted. The Tab key changes which column is highlighted.

Enter:

When an option appears highlighted on the screen, press Enter to choose that option.
After pressing Enter, you can press Escape and leave the screen. The option you
highlighted will be implemented.

Escape:

Returns the operator to the previous screen in the menu.

4.2 VT100 Terminal Screens

The 2361 modem uses a VT100 compatible Command/Modem port for connection to a terminal
or modem.

The rack modem requires an RJ-45 connection and the port is a DCE requiring a DTE
connection.

The standalone requires a DE-9 connection. This port can be set up as DCE or DTE by
positioning the slide switch on the front panel to the right position. Selecting the TRM option will
configure the port as a DCE and selecting MDM will configure the port as a DTE.

The following tables provide connector pin assignments for both the RJ-45 and the DE-9 ports.

The I/O assignments for the 8-pin modular, RJ-45 style (DCE only) on the rackmount version are:

Table 1. RJ-45 8-pin Modular Pin Out

Signal Name

Pin Number

Source

I/O

RI

1

DTE

O

DCD

2

DCE

O

DTR

3

DTE

I

SIG GND

4

DTE

I

RXD

5

DCE

O

TXD

6

DTE

I

CTS

7

DCE

O

RTS

8

DTE

I