Table 5: system alarm option definitions -11 – CANOGA PERKINS 2361 T1 Modem User Manual

Page 39

Advertising
background image

The EdgeAccess Universal Chassis System

2361 Modem Users Manual

4-11

Table 5: System Alarm Option Definitions

Alarm Name

Condition

Notification

LED

Modem

Redundancy Status

Reports the status of

the Remote and

Local, Primary and

Secondary Modems.

Active, Inactive and N/A

None

Configuration

Errors

Fiber connection

error, remote partner
error, (see CFG LED

error list in section

3.1.1)

OS, OLIM type, OLIM slot, ELIM

type, ELIM slot, Fiber line Setup

(see the note at the bottom of this

table)

CFG

Fiber Loss of Signal

Composite (fiber)

loss of sync

No, Yes

LOS

Electrical Loss of

Signal

Loss of signal to the

ELIM

No, Yes

LOS

Alarm Indication

Signal

Receiving AIS

OK

AIS

on

ELIM

Link Self Test

Status

The auxiliary BERT

(which is always

running) is out of

sync.

OK, Bad, and NA (NA indicates

composite loss of sync)

TST

SQL Primary

Indicates inadequate

signal quality through

fiber. A possible

indicator of poor

quality fiber.

OK, Bad

SQL

on

OLIM

Optical Transmit

Level

Certain OLIMs allow

monitoring of

transmission power

(light level). Indicates

condition of optic

signal.

OK, Bad, or NA, if OLIM that

supports this feature is not present.

SQL Secondary

Indicates condition of

optic signal in

secondary

(redundant) OLIM.

OK, Bad, NA

Chassis

Management

Indicates presence of

an operative DMM

anywhere in the

domain (even in a

different chassis).

OK: A functioning DMM is present
OFF: No DMM is present
BAD: The Proprietary Chassis Link,
or the DMM itself is not
functioning properly