4 alarm functions and default settings, 4 alarm functions and default settings -9 – CANOGA PERKINS 2361 T1 Modem User Manual

Page 37

Advertising
background image

The EdgeAccess Universal Chassis System

2361 Modem Users Manual

4-9

1. From the Main Menu, type "1"

and press Enter, to open the
System Configuration screen.

2. Type "4" to open the Alarm

Output Configuration screen.

3. The Alarm Output

Configuration screen appears.
There are nine configurable
alarm states, listed by number
(See Table 4).

4. To configure a particular alarm,

begin by typing its number in
the list and pressing Enter.

5. Use the space bar to toggle

through alarm choices: Major,
Minor or Off.

6. Press Enter to confirm the

alarm configuration choice.

Figure 28. The Alarm Output Configuration Screen

4.4.4 Alarm Functions and Default Settings

The table below describes each alarm's function and its factory default setting.

Table 4: Alarm Output Configuration Option Definition

Alarm Name

Function

Default

Factory

Setting

1 Active Composite Link Alarm Enables or disables alarms 2 through 9

Major

2 Electrical LOS

Loss of signal received from attached
equipment

Major

3 Electrical AIS Alarm

"All 1's" signal pattern received from
attached equipment

Minor

4 Configuration Alarm

Incompatibility between local and
remote modem, or between main
modem module and the LIMs attached
to it

OFF

5 Power Supply Alarm

Failure of power supply in the remote
chassis

Minor

6 Test Alarm

Failure of Bit Error Rate Test (BERT) or
failure in the continuous self-test
operation

OFF

7 Link Self Test Alarm

Failure of fiber between Local and
Remote units

Minor

8 Power On Self Test Alarm

Failure of Power-On self-test

Major

9 Inactive Composite Link
Alarm

In a redundant configuration, failure of
the redundant or inactive link

Minor