CANOGA PERKINS 2361 T1 Modem User Manual

Page 40

Advertising
background image

The EdgeAccess Universal Chassis System

2361 Modem Users Manual

4-12

Alarm Name

Condition

Notification

LED

Alarm Relay Inputs

On Standalone

modem only,

indicates presence of

Major and Minor

alarms

Major, Minor, None, and "Maj & Min"

Power Supply

Primary

Indicates condition of

primary power supply

OK: Power supply is operative
BAD: Power supply is detected by
The CIM, and known to be
bad.
N/A: A CIM is not present, not
functioning correctly, or the
chassis backplane has a
problem.

Power Supply

Secondary

In rack unit, indicates

condition of

secondary power

supply, if available.

OK: Power supply is operative
BAD: Power supply is detected by
The CIM, and known to be
bad.
N/A: A CIM is not present, not
functioning correctly, or the
chassis backplane has a
problem.

The Configuration Error Line Notifications are interpreted as follows:

OS - active software version is different either at the local, local redundant, remote, or remote

redundant unit.

OLIM type - local and remote OLIM types are not compatible.

OLIM slot - a known invalid card is inserted in the OLIM slot.

ELIM type - local and local redundant ELIM types are not compatible for redundancy.

ELIM slot - a known invalid card is inserted in the ELIM slot.

Redundancy - the local and remote modems are not compatible for redundancy, one modem

is redundant and the other is not.

Fiber Line - fiber cable is not properly installed (i.e. cable is not properly connected from

local Tx connector to remote Rx connector, or cable is not properly connected (primary
connected to secondary instead of primary).

Setup - all the online modems have discrepancies on: modem rate, loopback control mode,
line coding, framing, or switch over mode.