1install a clim in a bam host, Install a clim in a bam host -2, Figure 3. sw1 location -2 – CANOGA PERKINS L312 Ethernet Media Converter User Manual
Page 12: Table 1. sw1 functions -2
![background image](/manuals/651340/12/background.png)
EdgeAccess Universal Chassis System
L312 Ethernet Media Converters
2-2
SW1
Figure 3. SW1 Location
Table 1. SW1 Functions
Function
On
Off
ALM
Enable Alarm
Disable Alarm
EXT
Enable Link Loss Forwarding (LLF)
propagating from Extension Port to
User Port
Disable LLF propagating from
Extension Port to User Port
USR
Enable LLF propagating from User
Port to Extension Port
Disable LLF propagating from User
Port to Extension Port
LLE
Enable Link Loss Echo (LLE)
Disable LLE
2.2.1 Install a CLIM in a BAM Host
Each BAM can hold up to two CLIMs. See Figure 4.
Follow these steps to install the BAM and the CLIM:
Step 1. Insert a BAM into an available slot. Slide the BAM into the rails and push it firmly into the
backplane, then tighten the captive screws. If you encounter resistance, pull the BAM out
and check that no connector pins are bent on the BAM or the chassis backplane.
Step 2. Insert a CLIM into an unused slot in the BAM. Slide the CLIM into the rails and push it
firmly into the backplane, then tighten the captive screw. If you encounter resistance, pull it
out and check that no connector pins are bent on the CLIM or the BAM backplane.
If you encounter more difficulty, contact Canoga Perkins at (818) 718-6300 for technical assistance.
Note: CLIMs and BAMs are hot-swappable and can be inserted or removed without disrupting data
transfer in other application modules.