Set up baud rates and modem/slip/ppp parameters – CANOGA PERKINS 2346 T3 Fiber Optic Modem User Manual

Page 19

Advertising
background image

EdgeAccess Universal Chassis System

2346 T3 Modem

3-7

2. At the Alarm Output Configuration screen, type the number for an alarm and press <Enter>. See

Table 5.

3. Press <Space> to cycle to Enabled or Disabled and press <Enter>.

4. To return to the Main Menu, press <Esc>.

These selections do not affect how the CIM Major and Minor LEDs report alarms.

Table 5. Alarm Output Options

Alarm

When enabled, sends an alarm if. . .

2) LOS/CLS

Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail; default is Off

3) SQL

Squelch occurs (for received signal); default is Off

4) Configuration

The 2346 is set up incorrectly or the local and remote software versions
do not match; default is Off

5) Power/Fan

Power is low or fan is off; default is Minor

6) Power-On Self Test Modem failed when power was turned on; default is Major

7) BERT

Bit Error Rate Test (BERT) detects data errors; for details on BERT
results, see page 3-12; default is Off

Note: The Bit Error Rate Test (BERT) sends a continuous 127-bit sequence within the optical data

stream to check for bit errors while the optical signal remains in sync.

Set Up Baud Rates and Modem/SLIP/PPP Parameters

Although the default values for the communication parameters meet requirements for most systems,
you may need to change them for your particular situation.

To reset the VT100 baud rate, follow these steps:

1. At the Main Menu, type

4

, "Utilities," and press <Enter>.

2. At the Utilities menu, type

3

, "VT100 Baud Rate," and press <Enter>, then press <Space> to

cycle between 9600 and 19200 bps.

3. To return to the Main Menu, press <Esc>.

To access the Modem/SLIP/PPP Configuration menu, follow these steps:

1. At the Main menu, type

4

, "Utilities," and press <Enter>.

2. At the Utilities menu, type

4

, "Modem/SLIP/PPP Configuration," and press <Enter>.

3. To select the baud rate for the serial port, type

4

, "Modem/SLIP/PPP Configuration," and press

<Enter>, then press <Space> to cycle through the baud rate options; options include 9600, 19200,
38400, 57600, or 115200 bps.