11

User Information

DISTO classic

5

1.2.0 en

de

en

fr

it

es

pt

nl

da

sv

no

fi

jp

zh

ko

pl

hr

hu

ru

cz

el

Determination of a partial height with 3
points

Height determination between
point 1 and point 2 with three
measured points.

Press until

appears on the display; laser is activated and
"1 ---" starts blinking.
Aim at the upper point (1).

Trigger measurement; do not move the
instrument
!

Value is accepted and on the display "2 ---" starts blinking.

Trigger measurement; do not move the
instrument
!

Value is accepted.

appears on the display and "3 ---" starts blinking.

Press, a continuous measurement is triggered.

Move the DISTO a large amount around the ideal
measurement point.

Stop of continuous measurement. The height
and width are displayed between point 1 and 2
(Pythagoras).

User Information

Range

In daylight (outdoors) always work with laser viewfinder. If
neceesary, shade the target.

Increased range:
At night, at dusk and when target area is in the shade.

Reduced range:
By mat green and blue surfaces (also by plants or trees).

Rough surfaces

On a rough surface (e.g. coarse plaster) measure against
the centre of the illuminated area.
To avoid measuring to the bottom of plaster joints:
Use target plate, 3M "Post-it" or board.

Transparent surfaces

To avoid measuring errors, do not measure towards
colorless liquids (like water) or (dust free) glass.
For materials and liquids unfamiliar to you always take a
trial measurement.

Advertising