Do not connect the intercom system of AC power source.

Two modes for the Alarm Control Out are selected.
STD BY: This terminal is performed at only Standby mode

of the Mode Selection Switch when the SPOT MONI­

TOR CONTROL IN is activated by intercom or alarm

sensor/switch.

ALL MODE: This terminal is performed at either Standby or

On Mode of the Mode Selection Switch when the SPOT
MONITOR CONTROL IN is activated by intercom or
alarm sensor/switch.

The polarity for the alarm and Alarm Control Output of the

monitor should be matched.

The power rate of the alarm should be DC24V, max.

100mA.

If the power capacity of the alarm is less than 100mA at DC

24V, the alarm can be connected at the terminal of Alarm
Control Out directly.

If the power capacity of the alarm is more than 100mA at

DC24V, the alarm can not be connected at terminal direct­
ly. In this case, the relay circuit should be used for the

alarm.