10. Bright Control (BRIGHT)

Turn this control clockwise to increase the picture

brightness and turn this control counterclockwise to

decrease the picture brightness.

11. Bright Subcontrol

12. Contrast Control (CONTRAST)

Turn this control clockwise to increase the picture con­

trast and turn this control counterclockwise to
decrease the picture contrast.

13. Contrast Subcontrol (CONTRAST)

14. Picture Adjustment (PICTURE)

Turn this control clockwise for sharp picture and turn

this control clockwise for soft picture.

15. Audio Controi (AUDIO, MIN/MAX)

Turn this control clockwise to increase the audio level

and turn this control counterclockwise to decrease the
audio level,

16. Sequence / Setup Selection Switch

(SEQUENCE/SETUP)

Press this switch more than 2 seconds to display the
Set Up menu.

17. Camera Selection Switch (1)/ Up Switch ( A )

18. Camera Selection Switch (2) / Down Switch ( T )

19. Camera Selection Switch (3) / Left Switch (<^)

20. Camera Selection Switch (4) / Right Switch (►)

REAR VIEW

21. External Control Connection Terminals

RECOVER

When the picture of the camera is selected by the

signal of Spot Monitor Control In, the monitor only
displays the picture of the selected camera.

To reset the picture of the selected camera and to

set to the sequence operation for the Color CCTV
System, use the reset signal from the time lapse

VTR.

SPOT MONITOR CONTROL IN

The terminals of the Spot Monitor Control In are

used to connect the intercom or alarm sensors for

the spot monitoring by short circuit between termi­

nal 1,2, 3 or 4 and ground.

When the Camera Extension Unit is used, the

same spot monitoring are proceeded for terminal

5, 6 and 7 of the camera extension unit.

If the terminal 1 is shorted to the ground by inter­

com or alarm sensors, the camera No.1 is select­
ed and its picture is observed as spot monitoring.
The picture of the camera No.2, 3, 4, 5, 6, or 7
can be observed as the same way when the

Camera Extension Unit is used.

Note: The voltage of short circuit for terminal should be

0 - 0.2 volt when the intercom or alarm sensor is
activated.

ALARM CONTROL OUT

The terminals of the Alarm Control Out are used to

connect the buzzer or chime for sounding when
the terminals of the Spot Monitor Control In is
shorted to ground by intercom or alarm sensor.