A d j u s t m e n t & S e t t i n g

TX

M

ode

S

election

Data transmission formats are selected to meet the connected device’s and

system requirements.

AES/EBU Output

Select an output mode by DIP switch #1 on the rear panel.

The high sampling signal has a double density information than

the normal. There are two transmission modes extended form the
normal AES/EBU Tx mode. The AD converter transmits either one

of extended modes.

Tx mode

Channel/Wire

7a:

Rate

Typical device

AES/EBU(Normal)

2

44.1/48 kHz

Dual AES

(Dual Wire)

1

44.1/48 kHz

MTRs

Cenex Recorder

Hi-speed

(Single Wire)

2

88.2/96 kHz

Processors

Tc Electronics

y

Dual AES Output Card

This is an option card to enable the AD converter supplying

8 channel

output in Dual AES/EBU mode.

ADAX TDIF Output

An optical output : Dual track mode, 24 bit, 96 kHz, 4 channel is supplied.

Output channel

Selecting CHl-4 or CH5-8 is implemented in SHIFT operation mode.

WoRDCLOCK S

election

Wordclock In setting is required.

Wordclock In

The AD Converter examines input wordclcok frequency to have the internal

system clock synchronized to the input: 44,1, 88.2, 48 or 96 kHz. Contrary to
the Wordclock In, sampling frequency is selected manually on the front panel
by pressing the FREQ button.