C o n n e c t i n g t h e S y s t e m

C

onnecting

with

P

ro

T

ools

(C

onnection

4)

Wordclock master: Pro Tools

888 I/O

Connection

1. Connect SLAVE CLOCK OUT on the

888 I/O #1 and SLAVE CLOCK IN on

the

888 I/O #2 with a BNC cable. Then connect between #2 and #3 in

the same way as

#1 and #2.

2. Connect SLAVE CLOCK OUT on the

888 I/O #3 to WCK In on the DA

converter with a BNC cable.

3. Connect WCK Out on the DA converter and WCK In on the AD converter

#1 with a BNC cable. Then, connect between Wordclock-Out on the AD
converter #1 and Wordclock-In on the AD converter

#2

with a BNC cable.

In the same manner connect the AD converter #2, #3 and the DA
converter with BNC cables.

4. Connect AES/EBU Out on the AD converter #1 and AES/EBU In on the

888

I/O #1 with XLR cables. For #2 and #3 connect in the same manner.

5. Connect between the AES/EBU Out on the

888 I/O #1 and AES/EBU In on

the DA converter with XLR cables to monitor the sound.

Setting

1. Set SYNC MODE to “INTERNAL”, and select SAMPLE RATE from 44.1k or

48k on the

888 I/O #1.

2. Set Channel 1-8 INPUT to “DIGITAL”, and 1-2 FORMAT to “AES/EBU”on the

888 I/O #1-3.

3. On the AD converter select “EXT” by pressing the CLOCK button, and set

the DIP switch #7 to On and

#8 to Off to meet the REF level to -18 dBFS.

See “REF Level Setting”.