C o n n e c t i n g t h e S y s t e m

C

onnecting

with

the

ADAT & BRC

(C

onnection

2)

Wordctock master: WZ-AD96/96M AO Converter

•

Connection

1. Connect between Wbrdclock-Out on the AD converter and WCK In on the

DA converter with a BNC cable. In addition connect between WCK THRU

on the DA converter and 48 kHz In on the BRC with a BNC cable. Note

that inside the AD converter both CN907 and 908 jumpers are set to
“OUT” positions.

2. Connect between ADAT Out on the AD converter and Digital-In on the

ADAT with an optical cable to transmit 1-8 channel digital audio data.

3. Connect between DIGITAL Out on the ADAT and ADAT-In on the DA

converter with an optical cable to monitor the sound.

4. Connect between Remote Out to ADAT on the BRC and SYNC-In on the

ADAT .with a SYNC cable to control ADAT remotely and to take

synchronization.

•

Setting

1. On the AD converter, select “CRYSTAL” by pressing the CLOCK button to

let it work as the wordclock master. In addition select a sampling
frequency by pressing the FREQ button. Note that if 88.2 or 96 kHz is
selected , move the DIP switch

#6 to On to keep sending 44.1 or 48 kHz

wordclock to the BRC and ADAT.

2. Set the DIP switch on the AD converter #7 to Off and

#8 to On to meet

the REF level to -16 dBFS. See “REF Level Setting”.

3. On the AD converter, select output channels: 1-4 or 5*8: after entering the

SHIFT operation mode if 88.2 or 96 kHz is used. The selected channel
outputs will be recorded on the ADAT's tracks: output channels “1, 2, 3
and 4” or “5,

6, 7 and 8” will be recorded onto track 1/2, 3/4, 5/6 and 7/8

respectively.

(1) To enter the SHIFT operation mode press the WORD LENGTH button

for

2 second or more.

(2) Press the FREQ button to select output channels. The FREQ LEDs

indicate the selection.

CH 1-4; The FREQ LED 44.1k/88.2k lights.

CH 5-8: The FREQ LED 48k/96k lights.

4. On the BRC, select “48 k Input” by pressing the EXT SYNC switch to sync

to the wordclock.

3 4