SYSTEM ERROR TABLE

LED indication

Cause

Trouble points

SYS DATA RX

No data sync

Duplicated data sync

• Data Clock Switch on all units are set to

RCV position,

# Broken system data line with ’’RCV"

WJ-PCIO.

• Duplicated "SND" position of WJ-PCiO with

other units.

SYS DATA TX

Wrong Controller Unit No,

• Controller Unit No. is set either 0, 6, 7, 8 or

9 in PC-mode.

• Controller Unit No. is set other than 0 in

Extension-mode.

Duplicated Controller Unit No.

• Controller Unit No, duplicated with

WJ-PCiO in PC-mode.

RS-232 RX

75i7 termination error

• Broken or non-termination of system data

line with"SND" WJ-PCiO.

RS-232 TX

WJ-MP404 site error in PC-mode

• Duplicated "SND’' position of WJ-PCiO with

WJ-MP404.

• Duplicated "Unit No." of system components.

• Broken or non-termination of system data

line.