Cable connection – Panasonic WJ-PC10 User Manual

Page 8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

1.

RS-232C cable

Use RS-232C standard cable (straight connection)

of up to 49ft (15m) to connect between WJ-PCIO

and other unit such as Modem, computer and so on.

When the cable is to be made locally, refer to the

Pin configuration of RS-232C Connector on page 4,

2.

System data bus connection

2-1. Cable connection

The two BNC connectors for DATA IN/OUT on

the

WJ-MP404,

WJ-SQ508

and

WV-CU30D

are

internally connected and are identical. The System

data bus connection is looped through all units

with the first and last units being automatically

terminated with 75 ohms and all other units being

Hi-Z loop through.

2-2. Data Clock Switch selection

Set

the

Data

Clock

Switch

on

the

first

unit

connected to the System data bus to the "SND"

so that this unit is the Data Clock supplier. Set the

Data Clock Switch on all other units to the ’RCV”

position.

CABLE CONNECTION

Data are transmitted and received to and from each

unit connected to the System data bus, in addition

to the Data Clock, through the single coaxial cable.

WV-CU300

RCV

DATA IN/O UT DATA CLO CK

DATA IN/O UT

^NU| BIHCV

WJ-SQ508

SND

O (

DATAIN/C

DATA CLO CK

J

SND

in

RCV

JUT

WJ-PCiO

WJ-MP404

SND

WJ-SQ50e

- 6 -

Advertising