Panasonic WJ-PC10 User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

7-1. PC-mode

1. The numbers other than 1-5 on this switch are

not used.

2. Do not duplicate numbers with other

WV-CU300/WJ-PC10.

7-2. Extension-mode

1, Set this switch to number 0 for every WJ-PCi 0.

8. Data Clock Switch (DATA CLOCK SND/RCV)

When the data clock is supplied to this Data

Input/Output Connector(9), turn this switch to the

RCV position. And when the data clock is sent out

from this connector, turn this switch to the SND

position.

Note:

When the system is separated in some sites

connecting with the modem units and so on,

the SND-RCV connection should be made in

each site. In each site, only one unit should be

set as the SND unit and the other units should

be set as the RCV unit.

9.

Data Input/Output Connector (DATA IN/OUT 1 /2)

These connectors send out or accept the system

data to/from other system components in System

300. Also the data clock signal is either sent out or

received through these connectors.

10. 12VDC Input Terminals (DC 12V IN)

Supply 12VDC power to this terminals.

Caution:

Use class 2 power supply only.

- 5 -

Advertising