1. Move the cursor to the FLM/FRM parameter.

2. Select FLM (field) or FRM (frame).

Note:

When FRM is selected, ELC is set to OFF auto­

matically.

3. Electronic Light Control Setting

(ELC)

The electronic light control function eliminates inter­

ference by strong background lighting which
makes the camera picture dark, such as a spot­

light. In the ELC mode, more photometric weight is

given to the desired point of the screen (to where
the important object is located).

3. Move the cursor to the AREA parameter and select

the desired detection area. You can select the

desired detection area from followings.
ALL: All areas on the monitor screen are detected,
MANU: Detection areas are selectable manually.

See below for details,

CENTER: The photometric weight is given to the

center of the monitor screen.

S CIRCLE (Small Circle): The photometric weight

is given to the areas in the small circle of the

monitor screen.

M CIRCLE (Medium Circle): The photometric weight

is given to the areas in the medium circle of the
monitor screen.

L CIRCLE (Large Circle): The photometric weight

is given to the areas in the large circle of the
monitor screen.

** SET UP **

CAMERA ID

*OFP

FLD/FRM

FLD

ELC

t'ONl

SHUTTER

OFF

GAIN

AUTO

SYNC

INT

BLACK BAL

ABC

SCENE FILE

♦SCENEl

EHD

3-1. ELC detection control area setting (ELC CONT)

1, Select ON for the ELC ON/OFF selector on the front

panel of the camera control unit. Then confirm the
ELC parameter is ON.

2. Move the cursor to the ELC parameter and press

the PAGE button.

The ELC CONT menu appears.

** ELC СОИТ **

AREA

;ALL

PEAK/AVE P--------1.

RET EHD

Each time you press

changes as follows.

or ►, the parameter

ALL—► MANU —► CENTER —* S CIRCLE (Small Circle)

u

M CIRCLE (Medium Circle)

L CIRCLE (Large Circle)

ALL

Detection Area

/

ПППППППП

ПППППППП

ШПППППП

□□□□□□□□

ПППППППП

.ПППППППП

CENTER

Detection Area

П □

/

V

\~

--

■■nnrirjg

■■□ПППИ

□ □

i □ □

— 50% Sensing

Area

—100% Sensing

Area

S CIRCLE

Detection Area

/

!

/

Ш

■ ■

Ш

■ ■

>

-