1.3 S

PECIFICATIONS

1.3.1

Electrical Specifications

Parameter

CHC-LCD-30

Rated Charge Current

30 Amps

Rated Load Current

30 Amps

Typical Idle Consumption

At idle < 5mA

Maximum Solar Input Voltage

48V DC

Rated Working Voltage

12V DC or 24V DC Battery Systems

Float Charging Voltage

(adjustable)

13.8V DC 27.6V DC

Low Voltage Protection

(adjustable)

10.7V DC 21.4V DC

Low Voltage Recovery

(adjustable)

12.5V DC 25.0V DC

No Load Loss

<30mA

Loop Voltage Drop

<170mV

Temperature Compensation

-4.0 mV/Cell/

o

C

1.3.2

Physical Specifications

Parameter

Value

Dimension (H x W x D)

3.54” (90mm) x 7.40” (188mm) x 1.89” (48mm)

Unit Weight

12.7 oz. (360g)

Operating Temperature

14

o

F to 140

o

F (-10

o

C to 60

o

C)

Operating Humidity

<90% relative humidity (non-condensing)

Wire Size

Up to 16mm

2

(7AWG)

2 INSTALLATION

Insure all terminating connections are clean and tight to prevent arcing and overheating.
The controller must be installed in an area that satisfies all of the following conditions:

1. Dry: Avoid any location where water can contact the controller
2. Cool: Ambient air temperature between 30°F and 105°F (0°C and 40°C)
3. Ventilated: Allow at least 4 in (10 cm) of clearance above and below and at least 1 in (25 mm) on

each side for proper air flow.

2.1 E

LECTROSTATIC

(ESD)

P

RECAUTIONS

All electronic circuits may be damaged by static electricity. To minimize the likelihood of electrostatic
damage, discharge yourself by touching an electrical ground (e.g.: copper pipe) prior to handling the unit and
avoid touching components on the circuit boards. The risk of electrostatic damage is highest when relative
humidity is below 40%.

2.2 M

OUNTING

Mounting is optional; however, the environment must be dry and protected from water.

1. The controller can be mounted on a vertical or horizontal surface. If mounted vertically, the unit

should be oriented such that neither end is at the top so foreign material cannot settle into the
unit.

2. Install four user-supplied fasteners through the four mounting slots and into the mounting

surface.

3. Tighten all the fasteners to ensure the controller cannot slide in any direction.