A360 P

ersonAl

M

ixer

U

ser

G

Uide

A-Net In

The Cat-5 A-Net In port is fitted with a Neutrik® EtherCon® RJ45, and accepts either Pro16 or Pro16e A-Net

data. Cables used with the A360 can be the standard Cat-5e UTP cable with RJ45 ends commonly used

with computer systems or those fitted with the heavy-duty locking Neutrik EtherCon plug.

When connected to an A-Net distributor such as the D800 or A-16D Pro, the A360 also receives DC power

over the same Cat-5e data cable. In this case an external DC power supply is not required.

P

N

ote

:

When the A360 is connected to an A-Net distributor, the type of A-Net received (Pro16 or

Pro16e) is dependent on the input device that is supplying A-Net to the distributor. Both data

types are compatible with the A-Net distributors.

Mono Mix Out

A-Net In

Data

24VDC

Regulated

500 mA

CUSTOM

PROGRAM

DEFAULT

Pro16

Stereo Mix Out

Mono Mix Out

A-Net In

Data

24VDC

Regulated

500 mA

CUSTOM

PROGRAM

DEFAULT

Pro16

Stereo Mix Out

A-Net In and DC power connections

DC Power

The DC Power jack accepts a 24VDC power supply when the A360 is not being powered over the Cat-5

cable from an A-Net distributor. Use only an approved 24VDC, regulated 500mA supply such as the

optional Aviom PS-120 Power Supply.