Checkline TI-CMXDL User Manual

Page 16

Advertising
background image

DEFAULT SETUP: Loads a basic default setup. Use only as a last resort when the setups
in the TI-CMXDL have been corrupted and a computer is not accessible. Refer to section
12.4 for further info.

LANGUAGE: Provides the user the ability to select different languages for the
TI CMXDL. Refer to section 12.4 for further info.

3.7 DATA

Menu

NEW: Allows the user the ability to create a new alpha
numeric grid, or sequential log file with auto identifiers.
Equipped with custom parameters, rows, and columns
depending on the users application reporting requirements.
Refer to page 49 for further info.

EDIT: Gives the user the ability to change parameters of grid or sequential file previously
saved. Note: Pre-defined coordinates cannot be changed once they have been created.
Refer to page 57 for further info.

OPEN: This function provides the user with the ability to recall grids or sequential log
files that currently exist in memory, from a list of grids. Refer to page 58 for further info.

CLOSE: Provides the user the ability to close a currently opened grid or sequential log
file. Refer to page 59 for further info.

DELETE ONE FILE: This function provides the user with the ability to delete one
individual grid or sequential log file from a list of multiple grids/files previously saved in
memory. Refer to page 57 for further info.

DELETE ALL DATA: This function provides the user with the ability to delete all files
currently stored in memory. Refer to page 57 for further info.

3.8 UTIL (utilities) – Menu

SCAN MODE: This function enables a hi speed scan mode
that increases the overall sample rate from 65 to 200 measure-
ments per second, depending on the current measurement
mode used. Refer to section 10.2 for further info.

ALARM: Toggles alarm mode on, off, or audible. Refer to
section 10.3 for further info.

ALARM HIGH: Gives the user the ability to set the HI limit
parameter. If the measurement exceeds this value, a red light will illuminate and sound the
internal beeper. Refer to section 10.1 for further info.

ALARM LOW: Gives the user the ability to set the LO limit parameter. If the
measurement falls below this value, a red light will illuminate and sound the internal
beeper. Refer to section 12.4 for further info.

DIFFERENTIAL: Gives the user the ability to set a nominal value and the TI-CMXDL
will display ± the difference from the nominal value entered. Refer to section 10.2 for
further info.

3.9

XFER (transfer) – Menu

BACKUP SETUPS: Enables the user the to backup setups
currently stored in the TI-CMXDL to a PC via RS232 port.
Refer the help section of the TI-CMXDL Datacomm software
for an electronic manual.

-16-

Setting the Bottom Right(Grid) or End ID(Seq)

1. Use the UP and DOWN arrow keys

to scroll through the new Grid or Seq
List Items until LOWER RIGHT or
END ID is highlighted.

2. Press the ENTER key to activate the

Coordinate or End ID Edit Box.

3. GRID LOG: Use the LEFT and

RIGHT arrow keys to scroll the
Columns, and the UP, DOWN arrow
keys to scroll the Rows.

SEQ LOG: Use the UP, DOWN,
LEFT, and RIGHT arrow keys to
highlight the appropriate alpha
characters. Press the ENTER key
to select a character and advance to
the next character field, in conjunction
with using the CLR key to backspace
if necessary.

4. Press the OK key to select the

coordinate or end ID and return to the
Grid or Seq List Items screen, or
ESC to cancel the selection and
return to the Grid or Seq List Items
menu.

NOTE: If there is not enough memory available to create the grid or sequential log, an
error message box NOT ENOUGH MEMORY will be displayed. Press the OK or ESC
key to return to the Grid or Seq List Items menu. It may be necessary to free some mem
in the TI-CMXDL at this time. Refer to page 56 for more information on Deleting a Fil

Selecting the Auto Increment Direction

The Auto Increment feature gives the user the ability to specify which direction to advan
the cursor after storing a reading.

-53-

Grid Log

Sequential L

Grid Log

Sequential L

Grid Log

Sequential Log

Advertising