Checkline TI-CMXDL User Manual

Page 24

Advertising
background image

-24-

Material

sound velocity

sound velocity

in/us

m/s

Aluminum

0.2510

6375

Beryllium

0.5080

12903

Brass

0.1730

4394

Bronze

0.1390

3531

Cadmium

0.1090

2769

Columbium

0.1940

4928

Copper

0.1830

4648

Glass (plate)

0.2270

5766

Glycerine

0.0760

1930

Gold

0.1280

3251

Inconel

0.2290

5817

Iron

0.2320

5893

Cast Iron

0.1800

(approx)

4572

Lead

0.0850

2159

Magnesium

0.2300

5842

Mercury

0.0570

1448

Molybdenum

0.2460

6248

Monel

0.2110

5359

Nickel

0.2220

5639

Nylon

0.1060

(approx)

2692

Platinum

0.1560

3962

Plexiglas

0.1060

2692

Polystyrene

0.0920

2337

PVC

0.0940

2388

Quartz glass

0.2260

5740

Rubber vulcanized

0.0910

2311

Silver

0.1420

3607

Steel (1020)

0.2320

5893

Steel (4340)

0.2330

5918

Steel Stainless"

0.2230

5664

Teflon

0.0540

1372

Tin

0.1310

3327

Titanium

0.2400

6096

Tungsten

0.2040

5182

Uranium

0.1330

3378

Water

0.0580

1473

Zinc

0.1660

4216

Zirconium

0.1830

4648

Acoustic Velocity Table

10.0 ADDITIONAL FEATURES OF THE TI-CMXDL

10.1 High Speed Scan

The High Speed Scan feature of the TI-CMXDL increases the overall repetition rate to a
maximum of 140Hz with a high speed screen refresh rate of 25 times a second. This

feature enables a user to make scanned passes over an arbitrary length of the test materi

while still maintaining a reasonable representation of thickness over the scanned area or
region. This feature can be used in conjunction with High and Low alarm limits features
to dynamically keep track of both values. The feature is typically used to provide a bette
representation of the area scanned, by taking more readings at a faster rate repetition rat

The procedure to use the SCAN MODE feature is outlined below:

Using the Scan Mode

1. Press the MENU key once to activate the menu items tab.

Press the MENU key multiple times to tab right and the ESC
key multiple times to tab left until the UTIL menu is highlighted
and displaying the submenu items.

2. Use the UP and DOWN arrow keys to scroll through the sub

menu items until SCAN MODE is highlighted.

3. Use the LEFT and RIGHT arrow keys to toggle the

SCAN MODE on/off.

4. Press the MEAS key to return to the measurement screen.

10.2 Alarm Mode

The Alarm Mode feature of the TI-CMXDL provides the user with a method of setting t
erances, or limits, for a particular application requirement. This feature may be used for
variety of applications to verify the material is within the manufacturer specifications.
There are two limits, or alarm values, that can be setup in the TI-CMXDL – ALARM LO
and ALARM HIGH limits. However, the user may choose to activate and utilize only on
of the limit values, depending on their specific application requirements. The procedures
use the ALARM MODE feature are outlined below:

Toggle Alarm (on/off)

1. Press the MENU key once to activate the menu items tab.

Press the MENU key multiple times to tab right, and the
ESC key multiple times to tab left, until the UTIL menu is
highlighted and displaying the submenu items.

2. Use the UP and DOWN arrow keys to scroll through the

sub menu items until ALARM is highlighted.

3. Use the LEFT and RIGHT arrow keys to toggle the

ALARM on/off/audible.

4. Continue on to the next section “Setting the Alarm Low

Limi.t."

-45-